Functional introduction
The Modbus protocol is the most widely used protocol in the electronic industrial equipment, and now it has become a general industrial standard. Through this protocol, Modbus devices (such as PLC, DCS, HMI, and instruments) can communicate with each other through a network or serial port. But the Modbus protocol used in the serial port and the Ethernet network is different, so a gateway is needed to complete the communication conversion between the two protocols. ADM-5850Gis a modbus gateway product dedicated to connecting Modbus TCP devices and Modbus RTU/ASCII devices.
ADM-5850Ghas Modbus RTU/ASCII and Modbus TCP protocol conversion functions, it integrates Modbus TCP, Modbus RTU and Modbus ASCII protocol, and the device's serial port can be configured by software of RS-232, RS-485 or RS-422, you can easily achieve Modbus Ethernet devices with Modbus serial devices connected.
Product features
1, 32 bit ARM Cortex-m3 CPU
2, 1 Port 10/100MEthernet interface
3, Support RS-232, RS-422, RS-485 serial port mode
4. Baud rate, Data bit, Stop bit, Parity bit can be set
5. Integrated ARP, IP, ICMP, IGMP, UDP, TCP, DHCP, DNS,MODBUS TCP, MODBUS RTU, MODBUS ASCII protocol
6. Provide 4 mode of work:
RTU_ Master--TCP_ Slaver, TCP_ Master--RTU_ Slaver
ASCII_ Master--TCP_ Slaver, TCP_ Master--ASCII_ Slaver
7. Maximum support for 32 Modbus TCP master stations and 4 Modbus TCP slave stations
8. The automatic adaptive function of the time interval of the character
9, Provide ID mapping function to realize the management of host ID number
10. The local port, the target IP address, and the target port number can be set
11, Can be configured through Web Server, Telnet, MG Configuration tools
12, MG Configuration tools support
Windows98/me/NT/2000/XP/WIN7/WIN8/WIN10 operating system
13, Industrial design, can run steadily in bad environment
Product specification
Ethernet
Standard: 10/100Mbps adaptive Ethernet port
Communication mode: full duplex / half duplex adaptive
Transmission distance: less than 100 meters
Interface type: RJ-45
Serial port
RS-232 signals: TXD, RXD, RTS, CTS, GND
RS-422 signals: T+, T-, R+, R-
RS-485 signal: D+, D-
Parity bit: None\Even\Odd\space\mark
Data bits: 6bit, 7bit, 8bit
Baud rate: 300BPS to 230400bps
Direction control: RS-485 uses data flow direction automatic control technology
Load capability: RS-485/422 terminal support maximum 32 node polling
Transmission distance: RS-485/422 is 1000 meters, RS-232 is 10 meters
Interface protection: 1500W surge protection, 15KV ESD protection
Interface type: RS-232 terminal DB-9 male, RS-485/422 terminal
Power Supply
Power input: DC9~48V power supply
Power consumption: 120mA @ 24V (Max)
Environmental
Working temperature: -20 C~70 C
Storage temperature: -40 C~95 C
Storage humidity: 5 ~ 95% RH
Package size
Long x wide x high: 103x72x27 (mm)
Interface definition
RS-232:DB9 male head (TXD, RXD, RTS, CTS, GND)
RS-422: terminal (T+, T-, R+, R-)
RS-485: terminal (D+, D-)
Network interface: RJ45 (Ethernet)
Power interface: terminal VS+, VS-
Restore the default settings
Hardware recovery: Setup and GND short connection, the gateway reboot, and then disconnect Setup and GND, to restore the default settings.
Software recovery: Search the device through the MG Configuration tool software and click to restore the factory settings button.
LED instructions
Power indication: "PWR" bright red is the normal power supply
Modbus TCP connection success indication: "Active" is bright green
Serial data sending and receiving indication: "TX/RX" is Flash